The leading company for optical measurement

Luminance & Chromaticity Uniformity Analyzer UA-1000A


Discontinued

Outline

The UA-1000A moves up measuring speed and functionality compared with current model UA-1000.
The UA-1000A’s measuring time is about 5 sec, which is fastest level in the measuring instrument field.
(We reduce the measuring time to one third of that of the conventional our products.)

Features

■ Wide dynamic range : 0.005 – 100,000cd/m2
■ High resolution of 16bit : Make it possible to detect very slight difference in luminance and chromaticity
■ High resolution CCD camera : Max 1,360×1,024 pixel
■ Original optical system : Internal design and production

Principal use

■ Optical evaluation for FPD and its related field.
■ Uniformity in the luminance and the chromaticity of LCD, OLED.
■ Instrument panel in automobile and panel for car audio system.
■ Evaluation for light emission characteristics for various application.

Specifications

Photo detector 1.4 million-pixel Monochrome Cooled CCD
Objective lens Focal length 3-level switching system
f= 12.5mm(Wide), f= 25.0mm(Standard), f=50.0mm(Telephoto)
Spectral sensitivity characteristic Approximate into the CIE 1931 color-matching function
* This fulfills JIS Z 8724-1997 router condition.
Number of measurement points 1360×1024 (Binning1×1)
680×512(Binning2×2)
340×256(Binning4×4)
Luminance measurement range 0.005 – 100,000 cd/m2
Luminance linearity(*1) ±3%
Chromaticity accuracy(*1) ±0.005
In-plane unevenness uniformity(*2) Luminance : ±2%
Chromaticity : ±0.003
Repeat Characteristic Standard Mode
Luminance : 0.5% (2σ)
Chromaticity : 0.0020 (>0.001cd/m2 ), 0.0025 (≦0.01cd/m2)
High-Speed Mode
Luminance : 0.65% (2σ 0.1>cd/m2), 0.75%(2σ ≦0.1cd/m2)
Chromaticity : 0.004
Measurement Time(*3) Fastest about 5sec
Stability(*4) Luminance 1%
Repeatability(*4) Luminance 2%
Temperature characteristic Luminance ±3% (15 – 30℃ reference: 25℃)
Humidity characteristic Luminance ±3% (at 70% R.H and below, No condensation)
Interface USB 2.0
Power supply AC100 – 240V (50/60Hz)
Use conditions Temperature : 15 – 30℃, Humidity: 70%R.H. and below, No condensation
Outer dimensions (W×D×H) 210×294×244mm
Weight 6.9kg(Body), 9.6kg(with AL-UA1), 10.6kg(with AL-UA2)

(*1)Standard sources A, Luminance 0.005 to 100,000cd/m², evaluated on the center of the CCD.
(*2)Center of the CCD, standard sources A, Luminance is 30 cd/m².
(*3)Standard sources A, Binning 4×4, High-Speed Measurement Mode.
(*4)Standard sources A, evaluated on the center of the CCD.

Measurement field

Lens Type

Measuring distance(*)[mm]

750 1000 1250 1500 1750 2000 2250 2500
Wide Inch 23.5 30.5 37.6 44.6 51.6 58.6 65.7 72.6

Vertical

[mm]

477.5 619.5 764.0 906.3 1048.5 1190.8 1335.0 1475.2

Horizonal

[mm]

358.1 464.8 573.0 679.7 786.4 893.1 1001.3 1106.4
Standard

Inch

13.0 16.5 20.0 23.6 27.1 30.6 34.1 37.5

Vertical

[mm]

264.2 335.3 406.4 479.6 550.7 621.8 692.9 762.0

Horizonal

[mm]

198.1 251.5 304.8 359.7 413.0 466.3 519.7 571.5
Telephoto Inch 7.7 9.4 11.2 12.9 14.7 16.4 18.2 19.9

Vertical

[mm]

156.5 191.0 227.6 262.1 298.7 333.2 369.8 404.4

Horizonal

[mm]

117.3 143.3 170.7 196.6 224.0 249.9 277.4 303.3

(*)Measuring distance is from top of objective lens unit to object.

Operating condition

OS Windows XP Professional Service Pack 2 (32bit)
Windows Vista Ultimate Service Pack 2 (32bit)
Windows 7 Ultimate(32bit)
Windows 7 Professional(32bit)
CPU PentiumIV (2.8GHz) 以上
Memory 1GB or more
HDD 1GB or more
Port USB2.0 :2 port
*when conducting color correction, the UA-200 require RS-232C serial or USB 1.1
Display 1024×768 or more
1677 million color (32bit) or more
Others DVD-ROM drive

Accessories

Close-up attachment lens Model: AL-UA1 (4 – 16 inch on 553mm distance)
Close-up attachment lens Model: AL-UA2 (1.4 – 5.4 inch on 78.1mm distance)
Tripod Model: Tripod-UA
75-1, Hasunuma-cho, Itabashi-ku, Tokyo, 174-8580, Japan
TEL: +81-3-3558-2642, FAX: +81-3-5392-4992
Page Top